Updated:2023-02-15
Views:1482
Online Service
Four measurements in one sensor
Plug and play capability
Collect data remotely when used with the ZL6 data logger
Compact
Teflon screen protects the sensor from weather
Fast response
Integrated temperature for accuracy
Measurement Specifications | Relative Humidity(RH) |
Range:0-100%RH(0.00-1.00) Resolution:0.10% RH Accuracy:Sensormeasurement accuracy is variable across a range of RH Equilibration Time (r,63%):< 25 s (response time in 1 m/s air stream) Hysteresis: ±0.80% RH,typical Long-term Drift: ±0.25% RH/year, typical |
Temperature |
Range:-40.00 - 80.00°C Resolution:0.1°C Accuracy:+0.20℃ Equilibration Time(t.63%):< 165s(response time in 1 m/s air stream Long-term Drift:< 0.03 °C/ year, typical |
|
Vapor Pressure |
Range:0-47kPa Resolution:0.01 kPa Accuracy:Sensor measurement accuracy is variable across a range of temperatures and RH. |
|
Barometric Pressure |
Range:1-120 kPa Resolution:0.01 kPa Accuracy:+0.05 kPa at 25°C Equilibration Time(t,63%):< 10ms Long-term Drift:< 0.1 kPa/year, typical |
|
Communication Specifications | Output | DDI serial or SD1-12 communication |
Data Logger Compatibility | Anydata acquisition system capable of 4.0- to 15.0-VDC power and serial or SDI-12 communication. | |
Physical Specifications | Dimensions |
Diameter: 2.0 cm (0.8 in) Height: 5.4 cm (2.1 in) |
Operating Temperature Range |
Minimum:-40.00°C Maximum:80.00°C NOTE:Sensors may be used at higher temperatures under certain conditions:contact Customer Support for assistance. |
|
Cable Length |
5 m(standard) 75 m (maximum custom cable length) NOTE:Contact Customer Support if a nonstandard cable lengthis needed. |
|
Cable Diameter | 0.165 +0.004 in (4.20 +0.10 mm), with minimum jacket of0.030in(0.76 mm) | |
Connector Types | 3.5-mm stereo plug connector or stripped and tinned wires | |
Conductor Gauge | 22-AWG/24-AWG drain wire | |
Electrical and Timing Characteristics | Supply Voltage (VCC to GND) |
Minimum:4.0 VDC Maximum:15.0 VDC |
Digital Input Voltage(Logic High) |
Minimum:2.8V Typical: 3.6 V Maximum:5.0 V |
|
Digital Input Voltage(Logic Low) |
Minimum:-0.3V Typical: 0.0 V Maximum:0.8 V |
|
Digital Output Voltage(Logic High) |
Minimum: NA Typical:3.6 V Maximum: NA |
|
Power Line Slew Rate | 1.0 V/ms | |
Current Drain (During Measurement) |
Minimum:1.2 mA Typical: 3.5 mA Maximum:12.0 mA |
|
Current Drain (While Asleep) |
Minimum:NA Typical:0.03 mA Maximum: NA |
|
Power Up Time(DDI Serial) |
Minimum:NA Typical: NA Maximum:110 ms |
|
Power Up Time(SDI-12) |
Minimum:140 ms Typical:260 ms Maximum:400 ms |
|
Power Up Time(SDI-12, DDI Serial Disabled) |
Minimum: NA Typical:170 ms Maximum:200 ms |
|
Measurement Duration |
Minimum: NA Typical:50 ms Maximum:NA |
|
Other | Compliance |
Manufactured under ISO 9001:2015 2004/108/EC and 2011/65/EU EN61326-1:2013 EN50581:2012 |