DLI-600 spectrometer It is a new product in 2022. It is an elegant and easy to use device for spot checking photosynthetically active radiation (PAR) beyond the traditional range of 400 – 700 nm. DLI-600 measures the newly defined 400-750 nm ePAR radiation range, which has been proved to have extended photosynthetic activity characteristics. In addition to measuring ePAR, the DLI-600 meter also calculates Daylight Integration (DLI) and Photoperiod. EPAR, DLI and photoperiod affect plant growth and development. They are usually measured in greenhouses and growth chambers to help with light management and decision-making.
Accurate and stable measurement:Apogee research level quantum sensors have an accuracy drift rate of less than 2% per year, and all sensors are NIST traceable.
Measurement mode: This sturdy, waterproof and compact instrument is very suitable for single (spot check area) or continuous measurement of PPFD or ePPFD; DLI; And photoperiod. The DLI-600 instrument has two different screen modes to display measured values: storing data and viewing data in real time. In the Stored Data screen, it displays the DLI measurement, the optical period, and the date the data was collected (up to 99 days ago). The Live View Data screen displays the average ePPFD run in the last 2.5 seconds. Measuring and controlling DLI and the light time (photoperiod) received by plants is essential for optimizing plant health, triggering flowering and inducing other plant morphological effects. EPPFD, DLI and photoperiod data can be viewed on the screen or downloaded via USB-C data lines for analysis.
Rugged and ready to use: The DLI-600 is sturdy and durable, with the protection level of IP65, and can withstand harsh and humid environments. It can be carried around for spot check, placed directly on any horizontal surface, or connected to the commonly used camera tripod, fixture, or the standard used at the bottom ¼- 20 threaded ports. The DLI instrument consists of a cast acrylic diffuser (filter), an optical filter, a photodiode, a signal processing circuit, and an LCD display mounted in the ASA plastic housing. Each DLI package includes the instrument, a protective suitcase, two AAA batteries, a quick start guide, a screwdriver, a soil nail for easy installation, and a USB-C cable for downloading the data stored in the instrument to the computer as a CSV file.
Calibration Uncertainty | ± 5 % |
Measurement Repeatability | Less than 0.5 % |
Measurement Range | 0 to 4000 µmol mˉ² sˉ¹ |
Long-term Drift | Less than 2 % per year |
Field of View | 180˚ |
Spectral Measurement Range (± 5 nm) | 383 to 757 nm |
Directional (Cosine) Response | ± 5 % at 75˚ zenith angle |
Temperature Response | -0.11 ± 0.04 % per ℃ |
Response Time | 2.5 seconds |
Measurement Frequency | 3 minutes |
Data Log Capacity | 99 days (DLI & Photoperiod), 10 days (30 min PPFD/ePPFD averages) |
Non-linearity | Less than 1 % (up to 4000 µmol mˉ² sˉ¹) |
Stored Data Resolution (PPFD) | 0.1 µmol mˉ² sˉ¹ (when ≥ 1000, the screen will not display the decimal) |
Stored Data Resolution (DLI) | 0.1 mol mˉ² dˉ¹ |
Stored Data Resolution (Photoperiod) | 0.1 hours |
Connectivity | CSV file via USB-C data transfer |
ADC Resolution | 24 bits |
Operating Environment | -40 to 70 ℃ ; 0 to 100 % relative humidity |
Ingress Protection | IP65 |
Mounting Compatibility | Brass 1/4-20 threaded mount |
Battery Life | Approximately 6 months |
Dimensions | 1.91 W x 2.31 H x 0.93 D (inches) |
Mass | 67 g |
Warranty | 4 years against defects in materials and workmanship |
Manufactured | Made in the USA |