Updated:2024-04-25
Views:773
Online Service
A Kestrel DROP is the world’s easiest-to-use rugged environmental data logger. Available in three models – the Kestrel DROP D1 Temperature Logger, the Kestrel DROP D2 Temperature and Humidity Logger, and the Kestrel DROP D3 Temperature, Humidity and Pressure Logger – all three models allow you to monitor and record the conditions of any environment and easily access and chart real-time and historical data on your phone, tablet or other smart device.
The Kestrel DROP D2 data logger can be placed wherever needed to log temperature and humidity with the data logs retrieved wirelessly and automatically to the Kestrel LiNK app when within wireless range(up to 100’ or more line of sight).
Use a DROP Anywhere - Small, Accurate, Rugged and Waterproof
Each DROP measures just 1 x 1.8 x 2.4 inches (24 x 46 mm x 60 mm) and weighs just 1.2 ounces (34 grams). DROP loggers meet military and international standards for water, dust and shock resistance (IP-67 and MIL-STD-810G) and are conveniently equipped with a sturdy d-ring for hanging wherever needed.
DROPs Are Powered by the Kestrel LiNK App
Kestrel LiNK is the free app that powers the DROP loggers. With Kestrel LiNK on your smart phone or tablet, you can view real-time readings from any DROP logger within wireless range (up to 100’ or more line of sight) via Bluetooth Low Energy. Each phone or tablet can connect to up to 8 DROP loggers at the same time and store data logs from many more. Min/Max/Average readings are clearly displayed and the data log is viewable as a scrolling graph with detailed data for each logged point. The Kestrel LiNK app also allows adjustment of the logging interval and other settings as well as real-time threshold alerts. Readings can be updated as frequently as every 2 seconds and logging time and date are automatically updated whenever connected to your smart device. You can also send and share real-time and logged environmental data via email, Facebook or Twitter
The EASIEST way to monitor and track temperature, humidity, heat index and dew point in almost any environment – wet or dry, indoors or out
View data wirelessly via Bluetooth Smart on your iOS or Android phone or tablet with the free Kestrel LiNK app
Store thousands of data points and get months of logging on a single coin-cell battery - customize logging rate, connections and alerts
See, save and share data from multiple DROPs with just one phone or tablet
FEATURES
Drop-Tested to MIL-STD-810G
Floats
LiNK Wireless Communication to Mobile Devices (Bluetooth low energy)
Relative Humidity Sensor
Temperature Sensor (Patented External Isolated)
Waterproof to IP67 (3'/1M for 30 minutes)
Specifications
SENSORS | ||||
---|---|---|---|---|
SENSORS | ACCURACY (+/-) | RESOLUTION | SPECIFICATION RANGE | NOTES |
AmbientTemperature |
0.9 °F 0.5 °C |
0.1 °F 0.1 °C |
14 to 131°F -10 to 55 °C |
Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Battery Operational Temperature Limits. |
Relative Humidity | 2%RH | 0.1 %RH | 10 to 90% 25°C noncondensing | To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year. |
Pressure |
1.5 hPa|mbar 0.044 inHg 0.022 PSI |
0.1 hPa|mbar 0.01 inHg 0.01 PSI |
25°C/77°F 700-1100 hPa|mbar 20.67-32.48 inHg 10.15-15.95 PSI |
Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product. |
CALCULATED MEASUREMENTS | |||
---|---|---|---|
MEASUREMENT | ACCURACY (+/-) | RESOLUTION | SENSORS EMPLOYED |
Density Altitude |
226 ft 69 m |
1 ft 1 m | Temperature, Relative Humidity Pressure |
Dew Point |
3.4 °F 1.9 °C 15- 95% RH. Refer to Range for Temperature Sensor |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
Heat Index |
7.1°F 4.0°C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
THI (NRC) |
1.5 °F 0.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
THI (Yousef) |
2.3 °F 1.3 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
Wet Bulb Temperature - Psychrometric |
3.2 °F 1.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity Pressure |
ADDITIONAL PRODUCT INFO | |
---|---|
Response Time & Display Update | Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes. |
Data Storage | Logged history stored for every measured value. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. D1: >13,000 data points, D2: >7,000 data points, D3: >6,000 data points. |
Bluetooth® Data Connect Option | Wireless range up to 100ft|30m. Compatible with Kestrel LiNK app for iOS (model 4s and later) and select Android products (Android 4.3 and higher) (See website for complete list of compatible 3rd party apps). |
Certifications | CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards. |
Origin | Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B. |
Battery | User-replaceable CR2032 (included). |
Shock Resistance | MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller. |
Sealing | Waterproof (IP67 and NEMA-6) |
Battery Operational Temperature Limits | 0° F to 140 ° F | -18 °C to 60°C Measurements may be taken beyond the limits of the operational temperature range of batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading. |
Storage Temperature | -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C. |
Size & Weight | 2.4 x 1.8 x 0.9 in | 6 x 4.5 x 2.3 cm 1.2oz | 34g (Lithium battery included) |
Customer Service QQ
Customer Hotline:
Technical Supports