Large volume of influence
High measurement frequency
Easy to install
Plug and play capability with METER loggers
Simple integration with third-party loggers as a single-ended voltage reading
Volumetric Water Content(VWC) | Range | Mineral Soil Calibration:0.0000-0.5700 m³/m³(0%-57%VWC) |
Soilless Media Calibration:0.0000-0.6900 m³/m³(0%-69% VWC) | ||
Apparent Dielectric Permittivity (εa):1(air)to 80(water) | ||
NOTE:TheVWCrange is dependent on the media the sensor is calibrated to.Acustomcalibration will accommodate the necessary ranges for most substrates. | ||
Resolution | 0.0008 m³/m³(0.08% VWC) in mineral soils from 0-0.50 m³/m³(0%-50% VWC) | |
Accuracy | With standard calibration equation.0.03 m³/m³(3% VWC)tvpicalin mineralsoils that have solution electrical conductivity<10 dS/m | |
NOTE:With soil-specific calibration, ±0.02 m³/m³(±2% VWC) is typicalin any soil. | ||
Measurement Specifications | Measurement Volume | See comparison article |
Communication Specifications | Output | 300-1,250 mV, independent of excitation voltage |
Data Logger Compatibility | METERdataloggers(ZL6,EM50/60 series,Em5b) or any data acquisition systems capable of switched 3-15 VDC excitation and single-ended voltage measurement at greater than or equal to 12-bit resolution. | |
Physical Specifications | Dimensions |
Length:16.0 cm(6.3in) Width:3.3 cm (1.3 in) Height:0.8 cm(0.3in) |
Prong Length | 10.0 cm (3.94 in) | |
Operating Temperature Range |
Minimum:-40.00°C Typical: NA Maximum:50.00° |
|
NOTE:Sensors may be used at higher temperatures under certain conditions:contact Customer Support for assistance. | ||
Cable Length |
5 m(standard) 40 m (maximum custom cable length) |
|
NOTE:Contact Customer Support if a nonstandard cable lengthis needed. | ||
Connector Types | 3.5-mm stereo plug connector or stripped and tinned wires | |
Electrical and Timing Characteristics | Supply Voltage (VIN to GND) |
Minimum:3.0 VDC Typical: NA Maximum: 15.0 VDC |
Measurement Duration | Maximum:10 ms | |
Other | Compliance |
Manufactured under ISO 9001:2015 EM ISO/IEC 17050:2010(CE Mark) 2014/30/EU 2011/65/EU EN61326-1:2013 EN50581:2012 |
Customer Service QQ
Customer Hotline:
Technical Supports