The ES-2 Electrical Conductivity and Temperature Sensor is designed to measure the electrical conductivity of water in a pipe or tank. When you pair the new ES-2 with a TEROS 12 soil moisture sensor in the soil, you’ll begin to develop a complete picture of the salts that are going into your system, as well as the salts remaining in your soil or substrate.
GSA | View GSA details |
---|---|
Measurement Specifications | |
Temperature |
Range: –40 to 60 °C Resolution: 0.1 °C Accuracy: ±1 °C |
Bulk EC |
Range: 0 to 120 dS/m Resolution: 0.001 dS/m Accuracy: ±0.01 dS/m or ±10% (whichever is greater) |
Communication Specifications | |
Output | DDI serial or SDI-12 communication protocol |
Data logger compatibility | METER ZL6 data loggers and any data acquisition system capable of 3.6- to 15-VDC power and serial or SDI-12 communication |
Physical Specifications | |
Dimensions |
Length: 10.9 cm (4.30 in) Width: 2.4 cm (0.95 in) Thread: 1/2-in National Pipe Thread |
Operating temperature range |
Minimum: –40 °C Maximum: 60 °C NOTE: Sensors may be used at higher temperatures under certain conditions; contact Customer Support for assistance. |
In-line pipe connector type | 1-in Tee socket pipe fitting |
Cable length |
5 m (standard) 75 m (maximum custom cable length) NOTE: Contact Customer Support if a nonstandard cable length is needed. |
Connector types | 3.5-mm stereo plug connector or stripped and tinned wires |
Electrical and Timing Characteristics | |
Supply voltage (VCC to GND) |
Minimum: 3.6 V Maximum: 15.0 V |
Digital input voltage (logic high) |
Minimum: 2.8 V Typical: 3.6 V Maximum: 5.0 V |
Digital input voltage (logic low) |
Minimum: –0.3 V Typical: 0.0 V Maximum: 0.8 V |
Digital output voltage (logic high) | Typical: 3.6 V |
Power line slew rate | Minimum: 1.0 V/ms |
Current drain (during measurement) |
Minimum: 20 mA Typical: 20 mA Maximum: 28 mA |
Current drain (while asleep) | Typical: 0.03 mA |
Power up time (DDI serial) | Maximum: 100 ms |
Power up time (SDI-12) |
Minimum: 100 ms Typical: 200 ms Maximum: 250 ms |
Power up time (SDI-12, DDI disabled) | Typical: 125 ms |
Measurement duration |
Typical: 25 ms Maximum: 50 ms |
COMPLIANCE | EM ISO/IEC 17050:2010 (CE Mark) |