Products

current position:home page>Products>Measuring Instrument>Delta-T>

GP2 Data Logger and Controller

Updated:2023-04-28

Views:1495

  • Brand: Delta-T
  • Model: GP2
  • Description: The GP2 is a powerful 12 channel data logger that is easy to use, versatile, rugged and reliable. It can log most sensor types and accepts voltage, resistance, current, potentiometer, bridge, counter,
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

GP2 Data Logger and Controller Description:

User's Manual Getting Started Guide

GP2 Resource Centre

The Resource Centre contains a wide range of application information and tutorials – covering irrigation control, evapotranspiration, vapour pressure deficit, and much more. Visit the GP2 Resource Centre.

Power and flexibility

The GP2 Data Logger features advanced controller functionality, and sophisticated programs can be easily created via a simple scripting editor.

As the user’s needs change, the GP2 can adapt. An optional lid is available for additional cable entry points, or wider diameter cable entry points.

Building systems with the GP2 Data Logger

The GP2 is the ideal data logger for field work, with applications ranging from agronomy, meteorology and hydrology to eco-physiology and soil science. We can supply complete systems including sensors, enclosures, solar power and communications options.

The GP2 Data Logger is compatible with all Delta-T sensors. For the Delta-T WET Sensor there is a dedicated input channel.

Delta-T has decades of experience of instrumentation for environmental research and can advise on all aspects of system specification.

Sensors

The GP2 Data Logger can log most sensor types and accepts voltage, resistance, current, potentiometer, counter, frequency, and digital state inputs.

The GP2’s analog inputs can be fully customised. Each channel can have its own input type and recording parameters. DeltaLINK software gives the user control over reading frequency, thresholds and units, and provides statistical recording options for Average, Minimum, Maximum, Standard Deviation and more. Specialised wind options are available including wind rose, gusts and wind averaging.

Users can add their own custom sensor types to the sensor library, exploiting the GP2’s detailed configuration options. The GP2 provides 4 input ranges down to microvolt resolution with adaptive auto-ranging, excellent analog accuracy, and configurable sensor excitation – enabling it to support nearly all analog sensors.

Calculations based on the measurements from several input channels can be recorded and displayed as additional virtual channels (calculated measurements).

Ease of use

Simple point and click software makes it easy to configure channel set-up and recording intervals. The menus that support the advanced customisation options can be displayed or hidden as required.

Sensor connections are laid out logically with clear, easy-to-follow diagrams and notes.

The GP2’s weatherproof case, battery power and convenient accessories make it very easy to install in the field – often without the need for a secondary enclosure.

Simulator

This unique software feature allows logging programs to be tested before real-world activation. For applications involving weather data, irrigation or soil moisture recording, the environmental variables can be changed to test how the program responds. Years of logging time can be simulated in just a few minutes.

Storage, communications and power

4 MB of FLASH memory enable storage of 2.5 million readings (typical). Data can be collected by a laptop locally via USB/RS232 or remotely using the cellular modem options.

The GP2 has 6 alkaline AA internal batteries as standard. An optional mains power adapter is available (type GP2-PSU). Up to 7 GP2s can share power and communications using an M12 cabling network. GP1 Data Loggers can be integrated into such a network via an adapter cable.

Feature

Powerful and rugged field data logger

SDI-12 enabled

12 differential channels

Ideal for demanding research applications

Compatible with DeltaLINK-Cloud online data sharing platform

Calculation of full Penman-Monteith evapotranspiration equation

GP2 Data Logger and Controller Specification:

Input connections 12 differential (or 24 single-ended) analog inputs configurable as: Voltage, Resistance (12 3-wire or 24 2-wire), Bridge (12), Potentiometer (12)
4 digital inputs as: Counters, (2 fast + 2 slow), Frequency, Digital state
1 Delta-T WET sensor channel
Unlimited virtual channels
Serial input channel: 62 SDI-12 sensors or a single WET Sensor
Control outputs 2 relay outputs expandable to 6 (1 A)
Readings stored 2.5 Million
Recording rate 1 second to >24 hours
Configuration DeltaLINK
Communication options SDI-12, USB, RS232, ethernet or modem
Sensor excitation Calibrated 3 V reference, +5 V and +12 V regulated, or 5 to 10.5 V (battery or external power), user selectable
Power 6 AA alkaline batteries or external power 10-15 V DC
Battery life (dependent on usage) >310K readings, lasting 530 days
Enclosure rating IP65
Temperature range -20 to +60°C
Display -
Size 225 x 185 x 75 mm
Typical applications Demanding research projects
Environmental monitoring
Varied control applications
Sensor compatibility (maximum number of sensors that could be connected [1]
ML3 ✓ (6) with temp / (12) without temp
SM150T ✓(6) with temp / (12) without temp
PR2 ✓(2 PR2/6) (3 PR2/4)
PR2 SDI-12 ✓ (50) PR2/6
✓ (62) PR2/4
WET Sensor ✓ (1)
EQ3 ✓ 6 with temp / 12 without temp
Temperature ✓ (12)
Tensiometers ✓ (12)
Counters or Events ✓ (4) 2 fast 2 slow
Relay Output ✓(2) expandable to (6)