Updated:2022-11-30
Views:1247
Online Service
No measuring instrument can maintain its own accuracy, so it needs to be checked from time to time against the reference standard, and Vysala's HMK15 calibrator makes the calibration of humidity probe and transmitter and field inspection work is very simple and reliable. HMK15 operates on the principle that a saturated salt solution can produce a certain amount of relative humidity in the air above, and then the humidity probe or transmitter reading can be adjusted accordingly. This method is widely accepted and used in many * laboratories. Two or three different salt solutions are usually available depending on the use.
▪Easy to use, reliable performance, suitable for humidity probe and transmitter calibration
▪ Application design based on saturated salt solution
▪ Rapid temperature equilibrium
▪ No external power supply
▪Suitable for laboratory and spot inspection
▪The outer box and transport cover make the transport of HMK15 extremely convenient
▪ Pre-determined and certified calibration salt is available
▪Vaisala Service Center can provide approved calibration of humidity, temperature and atmospheric pressure.
**The methods used in the laboratory
HMK15 works based on the fact that a saturated salt solution produces a definite relative humidity in the air above it. The reading of humidity probe or transmitter can then be adjusted accordingly. This generally accepted and reliable method is used in many laboratories to calibrate humidity meters. There are usually two or three salt solutions used, with different calibration salts selected depending on the application.
Certified calibrated salt
HMK15 can be ordered with certified and pre-determined calibrated salt. Vaisala Measurement Standards Laboratory (MSL) will sample and calibrate each lot.
A calibrated thermometer
HMK15 can be ordered with a thermometer which is used to measure temperature during calibration. It can also be used to check the accuracy of the temperature measurement of the transmitter.
FINAS认可计量标准实验室
Vaisala Measurement Standards Laboratory is an accredited calibration laboratory of the Finnish National Laboratory (FINAS). FINAS is a member of the European Accreditation Cooperation Organization (EA).
Options and accessories available
|
||
A certified dose of salt:
|
Order Code:
|
Total uncertainty*:
|
LiCl salt 11 % RH
MgCl2, salt 33 % RH
NaCl, salt 75% RH
K2SO4, salt 97 % RH
|
19729HM
19730HM
19731HM
19732HM
|
(± 1.3 % RH)
(± 1.2 % RH)
(± 1.5 % RH)
(± 2.0 % RH)
|
* +20 °CWhen the uncertainty
|
||
Ion exchange water
Single salt tank
Carrying bag
|
19767HM
19766HM
HM27032
|
|
Customer Service QQ
Customer Hotline:
Technical Supports