Updated:2024-04-25
Views:774
Online Service
Get the environmental data you need for livestock and crop production and other farm and ranch activities.This lightweight, handheld, multi-function meter can be used inside and out for barn/facility condition assessments to spraying decisions where both wind speed and direction must be recorded. This comprehensive meter will deliver spot measurements, log and store data, and aid in auditing and record keeping. The Kestrel 5500AG is easily carried in a pocket or glove box and is ready to help whenever and wherever needed. Its rugged build and waterproof case mean it can work as hard as you do. Be prepared: be informed of local and micro-climate enivornments at your site.
Clip the Kestrel 5500AG into the optional Kestrel 5 Series Rotating Vane Mount and you have a sturdy weather station that can be left in place for days or weeks.
Spray Management
The Kestrel 5500AG provides Delta T measurements to aid in assessing acceptable spraying conditions and ensure you're within guidelines. Based upon ambient temperature and dew point, Delta-T provides guidance on the evaporation rate of sprayed chemicals to help you select the right spray nozzle. The compass provides direction to minimize spray drift. The Kestrel 5500AG calculates and logs on-site Delta T, wind speed, and direction without any additional user input. When combined with the Kestrel’s average wind and max wind gust measurements, agriculture professionals can ensure they spray safely, every time. Use an accessory carry pouch to keep your Kestrel handy on your belt, ready to go before any spraying operations.
Heat Stress Management with THI
THI (Temperature-Humidity Index), has been used for decades as a measure to classify heat stress risk in many livestock production and transportation operations. This measurement includes both temperature and relative humidity and is a basis for both strategic and tactical management practices which benefit animal health, productivity and well-being. The Kestrel 5500AG calculates and logs on-site THI based on user selection of either the NRC(National Research Council, 1971) or Yousef(Yousef, 1985) accepted THI calculations. Objective and accurate site-specific measurements are critical to ensuring a heat stress management strategy that is cost effective; and they're at your fingertips with the 5500AG.
Barn / Housing Ventilation Assessments
Regardless of the type of barn/house design all livestock require proper ventilation and air movement to maximize health, growth, and comfort. The Kestrel 5500AG provides wind speed and air flow measurements to quickly quantify air movement in the vicinity of livestock, locate drafts, measure fan effectiveness and confirm duct discharge velocity. Volume air flow takes duct shape and dimensions into account and allows for accurate comparison of various locations in a system. No calculator is needed to determine airflow with the Kestrel 5500AG – a few quick menu picks and built-in averaging gives you accurate readings instantly. For ducts that are out of reach, use the Kestrel LiNK app to view your Kestrel mounted on an extension pole with the Kestrel 5 Series Clip (requires LiNK option).
Microclimate, Harvest and Storage Conditions
Many livestock professionals also grow and store grains, hay and other feedstuffs. The Kestrel 5500AG can measure micro-climates around the farm to determine where mold and disease may be a problem, ensuring conditions are right for harvesting, drying, and storage. Leave the Kestrel 5500AG in place anywhere in the field, barn or greenhouse to get a graphical history of overnight conditions, (the Kestrel 5 Series Rotating Vane Mount and a ¼-20 camera clamp or tripod makes it easy).
Measures wind speed, temperature, humidity, Delta T, THI, air flow, direction and more.
Over 15 total meteorological parameters measured, calculated and displayed real-time and stored in memory, including advanced meteorological measurements such as dew point temperature, wet bulb temperature and density altitude.
Large, hi-res, hi-contrast, graphic display is perfectly readable in the brightest sunlight and is backlit for nighttime use.
FEATURES
Alarm Light
Backlight - Switchable White/Red
Battery Life Indicator
Data Log Graph View
Data Logging - Adjustable Interval
Date & Time
Digital Compass
Drop-Tested to MIL-STD-810G
FREE Kestrel LiNK Apps for Windows & Mac*
Integrated Flip Open Impeller Cover
Intuitive Tactile Up/Down/Enter Keypad
LiNK Wireless Communication to Mobile Devices (Bluetooth low energy)*
Minimum/Maximum/Average Reading
Pressure Sensor
Relative Humidity Sensor
Temperature Sensor (Patented External Isolated)
THI Warning Flag - Settable
Waterproof to IP67 (3'/1M for 30 minutes)
Specifications
SENSORS | ||||
---|---|---|---|---|
SENSORS | ACCURACY | RESOLUTION | SPECIFICATION RANGE | NOTES |
Wind Speed | Air Speed | Larger of 3% of reading, least significant digit or 20 ft/min Speed |
0.1 m/s 1 ft/min 0.1 km/h 0.1 mph 0.1 knots 1 B* 0.1 F/S* |
0.6 to 40.0 m/s 118 to 7,874 ft/min 2.2 to 144.0 km/h 1.3 to 89.5 mph 1.2 to 77.8 knots 0 to 12 B* 2-131.2* |
1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy -1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH|7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller |
Ambient Temperature |
0.9 °F 0.5 °C |
0.1 °F 0.1 °C |
-20.0 to 158.0 °F -29.0 to 70.0 °C |
Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits. |
Relative Humidity | 2%RH | 0.1 %RH | 10 to 90% 25°C noncondensing | To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year. |
Pressure |
1.5 hPa|mbar 0.044 inHg 0.022 PSI |
0.1 hPa|mbar 0.01 inHg 0.01 PSI |
25°C/77°F 700-1100 hPa|mbar 20.67-32.48 inHg 10.15-15.95 PSI |
Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product. |
Compass | 5° |
1° 1/16th Cardinal Scale |
0 to 360° | 2-axis solid-state magneto-resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout. |
CALCULATED MEASUREMENTS | |||
---|---|---|---|
MEASUREMENT | ACCURACY (+/-) | RESOLUTION | SENSORS EMPLOYED |
Air Density |
0.0002 lb/ft3 0.0033 kg/m |
0.001 lbs/ft3 0.001 kg/m3 |
Temperature, Relative Humidity Pressure |
Air Flow | 6.71% |
1 cfm 1 m3/hr 1 m3/m 0.1m3/s 1 L/s |
Air Speed, User Input (Duct Shape & Size) |
Altitude |
typical: 23.6 ft/7.2 m from 750 to 1100 mBar max: 48.2 ft/14.7 m from 300 to 750 mBar |
1 ft 1 m | Pressure, User Input (Reference Pressure) |
Barometric Pressure |
0.07 inHg 2.4 hPa|mbar 0.03 PSI |
0.01 inHg 0.1 hPa|mbar 0.01 PSI |
Pressure, User Input (Reference Altitude) |
Crosswind & Headwind/Tailwind | 7.1% |
1 mph 1 ft/min 0.1 km/h 0.1 m/s 0.1 knots |
Wind Speed, Compass |
Delta T |
3.2 °F 1.8 °C |
0.1 °F 0.1 °C | Temperature, Relative Humidity Pressure |
Density Altitude |
226 ft 69 m |
1 ft 1 m | Temperature, Relative Humidity Pressure |
Dew Point |
3.4 °F 1.9 °C 15- 95% RH. Refer to Range for Temperature Sensor |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
Evaporation Rate |
0.01 lb/ft2/hr 0.06 kg/m2/hr |
0.01 b/ft2/hr 0.01 kg/m2/hr |
Wind Speed, Temperature Relative Humidity Pressure, User Input (Concrete Temperature) |
Heat Index |
7.1°F 4.0°C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
Moisture Content | Humidity Ratio (“Grains”) |
4.9gpp .7g/kg |
0.1 gpp 0.01 g/kg |
Temperature, Relative Humidity Pressure |
Probability of Ignition (PIG) | PIG Accuracy dependent on proximity of inputs to reference table steps. | 10% | Temperature, Relative Humidity |
THI (NRC) |
1.5 °F 0.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
THI (Yousef) |
2.3 °F 1.3 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
Relative Air Density | .0.3% | 0.1% | Temperature, Relative Humidity Pressure |
Wet Bulb Temperature - Psychrometric |
3.2 °F 1.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity Pressure |
Wet Bulb Temperature - Naturally Aspirated (NWB TEMP) |
1.4 °F 0.8 °C |
0.1 °F 0.1 °C |
Wind Speed, Temperature Globe Temperature, Relative Humidity, Pressure |
Wind Chill |
1.6 °F 0.9 °C |
0.1 °F 0.1 °C |
Wind Speed, Temperature |
ADDITIONAL PRODUCT INFO | |
---|---|
Display & Backlight | Multifunction, multidigit monochrome dot-matrix display. Choice of white or red LED backlight. |
Response Time & Display Update | Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes. |
Data Storage & Graphical display Min/Max/Avg History | Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points. |
data Upload & Bluetooth Data Connect Option | Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC). |
Clock/Calendar | Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment. |
Auto Shutdown | User-selectable – Off, 15-60 minutes with no key presses. |
Languages | English, French, German, Spanish. |
Certifications | CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards. |
Origin | Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B. |
Battery Life | AA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use. |
Shock Resistance | MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller. |
Sealing | Waterproof (IP67 and NEMA-6) |
Display & Battery Operational Temperature Limits | 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading. |
Storage Temperature | -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C. |
Size & Weight | 5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included) |
Customer Service QQ
Customer Hotline:
Technical Supports