Updated:2023-02-24
Views:3632
Online Service
Improved algorithms increase accuracy
New one-minute read times
Measure thermal diffusivity and specific heat at a fraction of the cost
ASTM 5334- and IEEE 442-compliant
Controlled heating ensures heat is constant
Test setup easier than ever. Results displayed clearly
Mini USB cable makes downloading data easier
Automatically identifies the sensor you have plugged in and illustrates heating
Extended battery life lengthens use time
Portable: use in the field or in the lab
Measure moist and frozen materials accurately
Short heating times ensure no moisture movement
Measures thermal conductivity of many fluids
Robust sensor needles limit breakage
Each sensor engineered for a specific material
Automatically corrects for linear temperature drift
Resolves temperature to ±0.001°C
Operating Environment (Sensors) | Range | -50.00-150.00°C |
Operating Environment (Controller) | Range | 0.00-50.00°C |
Power | 5 AA batteries | |
Battery Life | More than 250 high-power measurements | |
Read Modes | Manual and unattended measurement modes | |
Data Storage | 2,048 measurements in flash memory (both raw and processed data are stored for download) | |
Physical Specifications | Controller |
Length: 18.5 cm (7. 28 in) Width: 10.0 cm (3.94 in) Height: 3.5 cm (1.38 in) |
Display Size |
Width: 5.5 cm (2.17 in) Height: 4.0 cm (1.57 in) |
|
Sensor Interface | DB-15 connector | |
Carrying Case |
Length: 37.0 cm (14.57 in) Width: 30.0 cm (11.81 in) Height: 10.5 cm (4.13 in) |
|
KS-3 (6 cm [small] single needle) | Range |
Conductivity: 0.02 – 2.00 W/(m • K) Resistivity: 50 – 5000 °C • cm/W |
Accuracy | Conductivity: ±10% from 0.2–2.0 W/(m • K) | |
Size | 1.3 mm diameter × 60 mm length | |
TR-3 (10 cm [large] single needle) | Range |
Conductivity: 0.10 – 4.00 W/(m • K) Resistivity: 25 – 1000 °C • cm/W |
Accuracy | Conductivity: ±10% from 0.1–4.0 W/(m • K) | |
Size | 2.4 mm diameter × 100 mm length | |
SH-3 (3 cm dual-needle) | Range |
Conductivity: 0.02 – 2.00 W/(m • K) Resistivity: 50 – 5000 °C • cm/W Diffusivity: 0.10 – 1.00 mm2/s Volumetric Specific Heat Capacity: 0.5000 – 4.2000 MJ/m3K |
Accuracy |
Conductivity: ±10% from 0.2–2.0 W/(m • K) Diffusivity: ±10% at conductivity above 0.2 W/(m • K) ±0.02 W/(m • K) from 0.10–0.20 W/(m • K) Volumetric Specific Heat Capacity: ±10% at conductivities above 0.1 W/(m • K) |
|
Size | 1.3 mm diameter × 30 mm length, 6 mm spacing | |
RK-3 (6 cm [thick] single needle) | Range |
Conductivity: 0.10 – 6.00 W/(m • K) Resistivity: 17 – 1000 °C • cm/W |
Accuracy | Conductivity: ±10% from 0.1–6.0 W/(m • K) | |
Size | 3.9 mm diameter × 60 mm length | |
Other | Compliance |
EN 61326-1:2013 EN 55022/CISPR 22 |
Customer Service QQ
Customer Hotline:
Technical Supports