Products

current position:home page>Products>Measuring Instrument>METER>

TEROS 06 Soil Temperature Profile Probe

Updated:2023-02-16

Views:1275

  • Brand: METER
  • Model: TEROS 06
  • Description: Soil temperature is critical for understanding the whole energy balance. It's often used in surface energy balance models and predictions. If you need a simple, accurate way to make temperature measur
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

TEROS 06 Soil Temperature Profile Probe Description:

User's Manual

More accurate than other sensors

The research-grade TEROS 06 soil temperature profile probe accurately measures and records soil temperature over time at six depths exceeding WMO recommendations. It is regularly used in the field and in lysimeters. TEROS 06 contains digital sensors at -5 cm, -10 cm, -20 cm, -30 cm, -50 cm, -100 cm. And, unlike other profile probes on the market, every TEROS 06 sensor is individually calibrated for the highest possible accuracy (±0.1°C).

Minimize soil disturbance

TEROS 06 has a small diameter of 20 mm to minimize soil disturbance, plus it was specifically engineered to eliminate heat transfer. The fiberglass-reinforced plastic body has a very low thermal conductivity, so there is no temperature carryover between profile layers. Stainless steel rings ensure excellent heat conductance from the soil to the sensor, so you know you’re only measuring soil temperature at a precise location.

Get more for less

Backed by 20 years of precision German engineering and painstaking attention to detail, the ultra-robust TEROS 06 is a high-quality, research-grade temperature profile probe that delivers the accurate soil temperature data you need for better models and predictions—with far less hassle.

Insanely simple setup

We designed the TEROS 06 soil temperature profile probe to be incredibly easy to install. Just auger a hole with the specially-made auger, and insert the probe. Then, plug the sensor into your ZL6 logger and start collecting data. It’s that easy. The logger auto-recognizes the TEROS 06 for simplified setup and configuration. The TEROS 06 also works with non-METER loggers.

Reliable data on the go

Easy and reliable data collection,maintenance,analysis,and sharing are all part of the TERos experience.Combine the TEROS 06 andZL6logger with ZENTRA Cloud. where all data are connected anddelivered anywhere in the world in near-real time.All you have to do is sit back and let the data flow.

Function:

Measures six depths exceeding WMO recommendations

Temp sensors at-5cm,-10cm,-20cm,-30cm,-50cm,-100c

Temperature accuracy:±0.1°C

Plug and play with ZL6 data logger

Visualize data instantly using ZENTRA Cloud

TEROS 06 Soil Temperature Profile Probe Specification:

Measurement Specifications Measurement Depths 5 cm,10 cm,20 cm,30 cm,50 cm,100 cm
Temperature Range:-20.00-50.00℃
Resolution:+0.03 °C
Accuracy: ± 0.1 °C (0°C to 30°C), ± 0.2°C (-20°C to 50°C)
Communication Specifications Output SDI-12 One-wire Serial Interface: DDI communications protocol,SDI-12 communications protocol
RS-485two-wire-serial-interface (M12 connector only):tensioLINK serial communications protocol,Modbus RTU communications protocol
Data Logger Compatibility METERZL6dataloggers and any data acquisition system capable of 3.8 - to28.0-VDC power and serial interface with SDI-12 and/or RS-485 interface, Modbus RTU or tensioLINK communication
Physical Specifications Dimensions Diameter:2.0 cm(0.79in)
Length:104.0 cm(40.94in)
Materials Shaft: PA66GF30
Sensor Elements:Stainless steel
Operating Temperature Range Minimum:-30.00°C
Maximum: 60.00°C
Cable Length 4.5 m (standard)
75m(maximum cable length using M12 connector and elongation cables)
Connector Types 3.5-mm stereo plug connector
4-pin M12 plug connector
Electrical and Timing Characteristics Supply Voltage (VCC to GND) Minimum:3.9 VDC continuous
Maximum:28.0 VDC continuous
Digital Input Voltage (Logic High) Minimum:1.9 V
Typical:3.6 V
Maximum:5.0 V
Digital Input Voltage (Logic Low) Minimum:-0.3 V
Typical:0.0 V
Maximum:1.0 V
Digital Output Voltage(Logic High) Typical:3.6 V continuous
Power Line Slew Rate Minimum: 1.0 V/ms
Current Drain (During Measurement) Minimum:2.0 mA
Typical:2.5 mA
Maximum:4.0 mA
Current Drain (While Asleep) Typical:80 μA
Power Up Time (DDI Serial Ready) Minimum:210 ms
Maximum:400 ms
Power Up Time(SDI-12 Ready, DDI Disabled) Minimum:210 ms
Maximum:400 ms
Power-Up Time(RS-485 Ready,DDI Disabled) Minimum:210 ms
Maximum:400 ms
Measurement Duration Minimum:30 ms
Maximum:240 ms
Other Compliance Manufactured under ISO 9001:2015
EM ISO/IEC 17050:2010 (CE Mark)

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com