UAT-610 Underground Utilities Locator Kit Description:

Datasheet

Multiple tracing modes allow you to locate and trace energized and de-energized utilities in a variety of applications

The intuitive Transmitter automatically chooses the correct locating function based on the connected accessory and includes selectable 8/33 kHz frequencies

The Receiver’s high-contrast display allows for clear viewing in full sunlight and features an automatic backlight for shaded and dark areas

Semi-automatic gain control quickly detects tracing signal and allows precise adjustment of the receiver sensitivity

Depth measurement up to 20 ft

Rated CAT IV 600 V, ensuring safety when working with energized cables

Rugged, durable construction: water and dust resistant to IP54 and drop proof to 3.28 ft (1 m)

Use the Signal Clamp to induce a signal without making electrical contact (included with the UAT-620)

Ground fault locating with the optional A-Frame accessory

Accidentally hitting a utility line during a project can lead to costly repairs and create hazardous public safety situations. Digging in the wrong place can also lead to unnecessary delays and costs for your project, and ultimately, your company. Avoid this disruption with the rugged and durable Amprobe UAT-600 Series, designed to accurately pinpoint underground utilities and buried services up to 100 feet deep with accurate depth measurement to 20 feet.

The locating kit comes complete and ready for use with a Transmitter, Receiver, test lead kit, batteries and additional fuses, all in a mobile, protective duffle bag. The UAT-620 kit also includes a Signal Clamp for transmitting a signal when it is not possible to make electrical contact with the cable to be traced. For applications where ground fault locating is required, use the UAT-600 Transmitter in combination with the optional A-Frame accessory.

Main applications

Locate energized 50/60 Hz cables carrying current

Identify the location of all metallic utilities: pipes*, energized and de-energized cables

Trace individual pipes* or cables (energized or de-energized)

Three testing modes for wide range of applications

Passive power mode (50/60 Hz) – tracing energized lines conducting current (no Transmitter necessary)

Passive radio mode (RF) – using surrounding radio waves to trace underground utilities (no Transmitter necessary)

Active mode using UAT-600-T Transmitter

Three active modes using the UAT-600-T Transmitter

Induction – the Transmitter will automatically start to radiate a signal around it using an internal antenna, used for tracing individual cables where there is no access to the line to connect test leads or a clamp

Direct connection with test leads – the most reliable method to trace individual cable or a pipe

Clamp (Included in the UAT-620 kit, optional for the UAT-610 kit) – provides an efficient and safe method of applying a locate signal to a cable, where it is not possible/safe to gain access to a cable for making an electrical contact

Special applications

2 frequency options: 8 kHz and 33 kHz

Locate non-metallic pipes and sewer lines

Take depth and current measurements

Measure voltage, resistance and output current

Advanced locating with two people

Locate ground faults with the optional AF-600 A-Frame accessory

Additional information

Measurement Category

CAT IV 600 V

Locates energized/de-energized wires, cables, pipes

Passive tracing - 50/60 Hz

Passive tracing - Radio

Active Tracing

33 kHz (de-energized) 8kHz (energized system)

Active tracing - Induction mode (33kHz)

Depth measurement

Up to 20 ft (6 m)

Signal Clamp accessory

(optional accessory)

A-Frame accessory

(optional accessory)

Null and peak tracing options

Display

LCD

Sonde capable

Auto display backlight sensing (Receiver)

Specifications

Features UAT-600-R Receiver UAT-600-T Transmitter SC-600 Signal Clamp (included with UAT-620, optional for UAT-610)
Measurement category CAT IV 600 V
Operating voltage/current 0 to 600 V 0 to 600 V, 100 A max.
Operating frequency/tracing modes Active tracing: 33 kHz and 8 kHz
Passive tracing: 50/60 Hz and Radio
Energized circuit
Induction mode: 33 kHz
Direct connection modes: 8 kHz and 33 kHz
Clamp mode: 8 kHz and 33 kHz
De-Energized circuit
Induction mode: 33 kHz
Direct connection modes: 8 kHz, 33 kHz, A-Lo/A-Hi
A-Frame: 8 kHz
Clamp mode: 8 kHz and 33 kHz
33 kHz and 8 kHz
Locating modes Peak and Null
Depth measurement and accuracy Up to 20 ft
4 in to 10 ft: pm; 3 %
10 ft to 20 ft: pm; 5 %
Display backlight Automatic Yes
Audio indication Increasing closer to the signal Fast beeps showing the better signal is applied
Transmitting mode power output Max. 3 watts
Output voltage Max. 50 V rms
Output current Max. 250 mA rms, constant current in 5 steps
Signal voltage output (nominal) 23 V rms at 8 kHz
30 V rms at 33 kHz
Mains voltage measurement 0 V to 600 V, 50 Hz to 60 Hz
Resolution: 1 V
Accuracy: pm; 10%
Resistance measurement
(De-energized circuit)
0 ohm; to 999 k ohm;
Range: 0 ohm; to 999 ohm; (resolution: 5 ohm;)
Range: 1 k ohm; to 999 k ohm; (resolution: 1 k ohm;)
Accuracy: pm; 10%
Output hazardous voltage warning ≥ 30 V rms
Mains hazardous voltage warning ≥ 30 V rms
Sensitivity adjustment (gain control) Yes
Sensitivity at 1 m (typical) Power: 2 mA
Radio: 20 μA
8 kHz: 5 μA
33 kHz: 5 μA
Display 4.3 in, 320 x 240 BW outdoor LCD display with auto backlight LCD display (LED backlight)
2.4 in x 1.3 in
Update rate Instantaneous Current (mA): 10 ms
Voltage (V): 15 ms
Resistance ( ohm;): 330 ms
Operating temperature and humidity -4 °F to 122 °F (-20 °C to 50 °C), ≤90% RH
Storage temperature and humidity -40 °F to 140 °F (-40 °C to 60 °C), ≤90% RH
Operating altitude < 6561 ft (< 2000 m)
Pollution degree 2
Water and dust resistance IP54
Drop proof 3.28 ft (1 m)
Power supply (6) 1.5 V AA alkaline batteries (8) 1.5 V D cell alkaline batteries
Auto power off 15 minutes idle
Battery life Approx. 35 hours at 70 °F (21 °C) (Typical) Approx. 16 hours at 70 °F (21 °C) (Typical)
Overload protection 600 V rms
Fuse FF 500 mA, 1000 V, IR 30 kA, Φ6.3×32 mm
Safety compliance IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033
IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033
IEC 61010-031, CSA/UL 61010-031 (test leads)
IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033
Size (H x W x L) Approx. 11.9 x 4.7 x 30.7 in (302 x 120 x 779 mm) Approx. 14 x 9 x 4.7 in (355 x 230 x 120 mm) Approx. 11.6 x 7.1 x 1.4 in (295 x 180 x 37 mm)
Weight Approx. 4.2 lb (1.9 kg) (batteries installed) Approx. 7.0 lb (3.2 kg) (batteries installed) Approx. 1.9 lb (0.85 kg)