AC940Datasheet
Miniature Industrial, Class I, Division 2 / Zone 2 Accelerometer, Top Exit 2 Pin Mini-MIL Connector, 100 mV/g, ±10%
36-900,000 CPM Frequency Response (±3dB)
-58 to 250 °F (50 to 121 °C) Temperature Range
Welded, Hermetic Sealing
CSA/ATEX Approved
Must use "Class I, Division 2" CB190 or CB296 Cable and JQ2A or JQ2N Connector
AC944Datasheet
Miniature Industrial Class I, Division 2 / Zone 2 Accelerometer, Side Exit 2 Pin Mini-MIL Connector, 100 mV/g, ±10%
36-600,000 CPM Frequency Response (±3dB)
-58 to 250°F (-50 to 121°C) Temperature Range
Welded, Hermetic Sealing
CSA/ATEX Approved
Must Use "Class I, Division 2" CB190 or CB296 and JQ2A or JQ2N Connector
AC933Datasheet
Low Capacitance, Class I, Division 2 / Zone 2 Accelerometer, Top Exit 2 Pin Connector, 50 mV/g, ±10%
48-900,000 CPM Frequency Response (±3dB)
-40 to 250 °F (-40 to 121 °C) Temperature Range
IP68 Sealing
Class I, Division 2 / Zone 2 Rating
Must Use "Class I, Division 2" CB190 or CB296 Cable and Q2A or Q2N Connectors
AC934Datasheet
Low Capacitance, Class I, Division 2 / Zone 2 Accelerometer, Side Exit 2 Pin Connector, 50 mV/g, ±10%
48-516,000 CPM Frequency Response (±3dB)
-40 to 250 °F (-40 to 121 °C) Temperature Range
IP68 Sealing
Class I, Division 2 / Zone 2 Rating
Must Use "Class I, Division 2" CB190 or CB296 Cable and Q2A or Q2N Connectors
AC935Datasheet
Low Capacitance, Class I, Division 2 / Zone 2 Accelerometer, Top Exit 2 Pin Connector, 100 mV/g, ±10%
30-900,000 CPM Frequency Response (±3dB)
-40 to 250 °F (-40 to 121 °C) Temperature Range
Welded, Hermetic Sealing
Class I, Division 2 Zone 2 Rating
Excellent for Higher g Applications
AC936Datasheet
Low Capacitance, Class I, Division 2 / Zone 2 Accelerometer, Side Exit 2 Pin Connector, 100 mV/g, ±10%
30-516,000 CPM Frequency Response (±3dB)
-40 to 250 °F (-40 to 121 °C) Temperature Range
Welded, Hermetic Sealing
Class I, Division 2 Rating
Excellent for Higher g Applications
AC931Datasheet
Low Capacitance, Class I, Division 2 / Zone 2 Accelerometer, Top Exit 2 Pin Connector, 10 mV/g, ±10%
60-900,000 CPM Frequency Response (±3dB)
-40 to 250 °F (-40 to 121 °C) Temperature Range
Welded, Hermetic Sealing
Class I, Division 2 / Zone 2 Rating
Must Use "Class I, Division 2" CB190 or CB296 Cable and Q2A or Q2N Connectors
TA931Datasheet
Low Capacitance, Class I, Division 2 / Zone 2 Dual Output Sensor, Acceleration and Temperature, Top Exit 3 Pin Connector, 10 mV/g, 10 mV°C, ±10%
72-900,000 CPM Frequency Response (±3dB)
-40 to 250 °F (-40 to 121 °C) Temperature Range
Welded, Hermetic Sealing
CSA/ATEX Approved, High Performance Sensor
Helps to Detect Bearing Defects and Temperature Changes
TA935Datasheet
Low Capacitance, Class I, Division 2 / Zone 2 Dual Output Sensor, Acceleration and Temperature, Top Exit 3 Pin Connector, 100 mV/g, 10 mV/°C, ±10%
30-900,000 CPM Frequency Response (±3dB)
-40 to 250 °F (-40 to 121 °C) Temperature Range
Welded, Hermetic Sealing
CSA/ATEX Approved
Must Use "Class I, Division 2" CB191 or CB298 Cable and Q3A or Q3N Connectors
TA936Datasheet
Low Capacitance, Class I, Division 2 / Zone 2 Dual Output Sensor, Acceleration and Temperature, Side Exit 3 Pin Connector, 100 mV/g, 10 mV°C, ±10%
30-516,000 CPM Frequency Response (±3dB)
-40 to 250 °F (-40 to 121 °C) Temperature Range
Welded, Hermetic Sealing
CSA/ATEX Approved
Must Use "Class I, Division 2" CB191 or CB289 Cable and Q3A or Q3N Connectors
TA938Datasheet
Low Capacitance, Class I, Division 2 / Zone 2 Dual Output Sensor, Acceleration and Temperature, Side Exit 3 Pin Connector, M8 Captive Bolt, 100 mV/g, 10 mV°C, ±10%
30-600,000 CPM Frequency Response (±3dB)
-40 to 250 °F (-40 to 121 °C) Temperature Range
Welded, Hermetic Sealing
CSA/ATEX Approved
Must Use "Class I, Division 2" CB191 or CB298 Cable and Q3A or Q3N Connectors
AC949Datasheet
Class I, Division 2 / Zone 2 Biaxial Accelerometer, Side Exit 3 Pin Connector, with X and Z Axis, 100 mV/g, ±10%
60-390,000 CPM Frequency Response (±3dB)
-58 to 250°F (-50 to 121°C) Temperature Range
Welded, Hermetic Sealing
CAS/ATEX Approved
Must Use "Class I, Division 2" CB191 or CB212 and D3Q Connector
AC950Datasheet
Class I, Division 2 / Zone 2 Triaxial Accelerometer, Side Exit 4 Pin Mini-MIL Connector, 100 mV/g, ±10%
36-600,000 CPM Frequency Response (±3dB)
-58 to 250°F (-54 to 121°C) Temperature Range
Welded, Hermetic Sealing
CSA/ATEX Approved
Must Use "Class I, Division 2" CB192 or CB218 Cable and J4Q Connector