AII Portable Oxygen Analyzers GPR-1000/1100/2000/3500 MO Description:

GPR-1100 User's Manual GPR-1000 User's Manual GPR-2000 User's Manual GPR-3500 MO User's Manual Datasheet

For Field Spot Checks from PPM to 100% Oxygen

Features

Measurement ranges from 0-10 ppm up to 0-100% O2

Up to 5 ranges per model with manual or auto-ranging feature

ATEX models are rated for IIC gases

Rugged design, proven to last in field operation

Lightweight (2.5Kgs) and easy to use

Up to 30 days battery life (40 hours with pump)

24 to 32 months sensor life span (in normal use)

Internal pump option

0-1V output

XLT sensor options for CO2 background

Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in their reliability and accuracy.

The Analytical Instruments concept of using the same HMI and menu structures for portable and online analyzers makes it extremely easy for operators to use both types of instruments on their site without need for extra training.

Specifications

GPR-1100 GPR-1000 GPR-2000 GPR-3500 MO
Measurement range 0-10, 0-100, 0-1000 ppm, 0-1%, 0-25% 0-1000 ppm, 0-1%, 0-25% 0-1%, 0-5%, 0-10%, 0-25% 0-100%
Accuracy < 2% of selected range at constant conditions < 2% of selected range at constant conditions < 2% of selected range at constant conditions < 2% of selected range at constant conditions
Response time T90 < 10 seconds T90 < 10 seconds T90 < 10 seconds T90 < 13 seconds
Recovery time 60 sec in air to < 10 ppm in < 1 hour on N2 purge 60 sec in air to < 100 ppm in < 15 min on N2 purge N/A N/A
Sensitivity (LDL) 0.05 ppm 5 ppm 0.01% 0.10%
Linearity < 1% of scale < 1% of scale < 1% of scale < 1% of scale
Sensor model GPR-12-333

XLT-12-333 for gas mixture with > 0.5% CO2
GPR-12-100-M

XLT-12-100-M for gas mixture with > 0.5% CO2
GPR-11-32-RTS

XLT-11-24-RTS for gas mixture with > 0.5% CO2
GPR-11-120-RTS
Sensor life at 25ºC (77°F) and 1 atm 24 months in < 1000 ppm O2 GPR-11-32-RTS 32 months in air
XLT-11-24-RTS 24 months in air
GPR-11-32-RTS 32 months in air
XLT-11-24-RTS 24 months in air
24 months in 100% O2
Calibration interval 30 days 30 days 30 days 30 days
Inlet pressure 0.34 - 2 barg (5-30 psig) with atmospheric vent 0.34 - 2 barg (5-30 psig) with atmospheric vent 0.34 - 2 barg (5-30 psig) with atmospheric vent 0.34 - 2 barg (5-30 psig) with atmospheric vent
Flow rate 0.5-1.0 l/m (1-2 SCFH) 0.5-1.0 l/m (1-2 SCFH) 0.5-1.0 l/m (1-2 SCFH) 0.5-1.0 l/m (1-2 SCFH)
Gas connections 1/8" NPT male quick connect 1/8" NPT quick connect 1/8" compression tube fittings 1/4" compression tube fittings
Wetted parts Stainless steel Brass connections; stainless steel optional GP version: Brass, plastic
ATEX version: Stainless steel flow housing, tubing and fittings
Stainless steel
Display Graphical LCD 7 x 3.5cm (2.75 x 1.375") Graphical LCD 7 x 3.5cm (2.75 x 1.375") Graphical LCD 7 x 3.5cm (2.75 x 1.375") Graphical LCD 7 x 3.5cm (2.75 x 1.375")
Resolution 0.01ppm 1ppm 0.00% 0.10%
Enclosure Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6cm (4 x 9 x 3")

3.64kg (8lbs)
Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6cm (4 x 9 x 3")

3.64kg (8lbs)
Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6cm (4 x 9 x 3")

3.64kg (8lbs)
Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6cm (4 x 9 x 3")

3.64kg (8lbs)
Compensation Barometric pressure and temperature Barometric pressure and temperature Barometric pressure and temperature Barometric pressure and temperature
Signal output 0-1V 0-1V 0-1V 0-1V
LED indicators LOW BATT (72 hr. warning); CHARGE mode LOW BATT (72 hr. warning); CHARGE mode LOW BATT (72 hr. warning); CHARGE mode LOW BATT (72 hr. warning); CHARGE mode
Operating temperature 5°C to 45°C (41°F to 113°F) (GPR sensor),
-10° to 45°C (14°F to 113°F) (XLT sensor)
5°C to 45°C (41°F to 113°F) (GPR sensor),
-10° to 45°C (14°F to 113°F) (XLT sensor)
5°C to 45°C (41°F to 113°F) (GPR sensor),
-10° to 45°C (14°F to 113°F) (XLT sensor)
5°C to 45°C (41°F to 113°F)
Power Rechargeable battery (lead acid) Rechargeable battery (lead acid) Rechargeable battery (lead acid) Rechargeable battery (lead acid)
Battery life Up to 30 days on a single charge (40 hours with pump running) Up to 30 days on a single charge (40 hours with pump running) Up to 30 days on a single charge (40 hours with pump running) Up to 30 days on a single charge
Area classification ATEX: Ex II 2 G
Ex ib IIC T4 Gb
Tamb: 5°C to +45°C
ATEX: Ex II 2 G
Ex ib IIC T4 Gb
Tamb: 5°C to +45°C
ATEX: Ex II 2 G
Ex ib IIC T4 Gb
Tamb: 5°C to +45°C
General purpose only