Updated:2023-09-12
Views:2362
Online Service
GPR-12-333 PPM O2 sensor is ideal for measuring oxygen 0-10 PPM in a gas mixture
GPR-1600
GPR-1200
GPR-1100
GPR-18
GPR-1800 Series
GPR-1500 Series
This innovative sensor design carries over many of the features of the traditional galvanic oxygen sensor but poses much higher sensitivity, stability and high signal to noise ratio with 24 months operating life thus offerring effective analyzer solution for measuring low levels PPM oxygen analysis.
GPR-1100 | GPR-1000 | GPR-2000 | GPR-3500 MO | |
Measurement range | 0-10, 0-100, 0-1000 ppm, 0-1%, 0-25% | 0-1000 ppm, 0-1%, 0-25% | 0-1%, 0-5%, 0-10%, 0-25% | 0-100% |
Accuracy | < 2% of selected range at constant conditions | < 2% of selected range at constant conditions | < 2% of selected range at constant conditions | < 2% of selected range at constant conditions |
Response time | T90 < 10 seconds | T90 < 10 seconds | T90 < 10 seconds | T90 < 13 seconds |
Recovery time | 60 sec in air to < 10 ppm in < 1 hour on N2 purge | 60 sec in air to < 100 ppm in < 15 min on N2 purge | N/A | N/A |
Sensitivity (LDL) | 0.05 ppm | 5 ppm | 0.01% | 0.10% |
Linearity | < 1% of scale | < 1% of scale | < 1% of scale | < 1% of scale |
Sensor model |
GPR-12-333 XLT-12-333 for gas mixture with > 0.5% CO2 |
GPR-12-100-M XLT-12-100-M for gas mixture with > 0.5% CO2 |
GPR-11-32-RTS XLT-11-24-RTS for gas mixture with > 0.5% CO2 |
GPR-11-120-RTS |
Sensor life at 25ºC (77°F) and 1 atm | 24 months in < 1000 ppm O2 |
GPR-11-32-RTS 32 months in air XLT-11-24-RTS 24 months in air |
GPR-11-32-RTS 32 months in air XLT-11-24-RTS 24 months in air |
24 months in 100% O2 |
Calibration interval | 30 days | 30 days | 30 days | 30 days |
Inlet pressure | 0.34 - 2 barg (5-30 psig) with atmospheric vent | 0.34 - 2 barg (5-30 psig) with atmospheric vent | 0.34 - 2 barg (5-30 psig) with atmospheric vent | 0.34 - 2 barg (5-30 psig) with atmospheric vent |
Flow rate | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) |
Gas connections | 1/8" NPT male quick connect | 1/8" NPT quick connect | 1/8" compression tube fittings | 1/4" compression tube fittings |
Wetted parts | Stainless steel | Brass connections; stainless steel optional |
GP version: Brass, plastic ATEX version: Stainless steel flow housing, tubing and fittings |
Stainless steel |
Display | Graphical LCD 7 x 3.5cm (2.75 x 1.375") | Graphical LCD 7 x 3.5cm (2.75 x 1.375") | Graphical LCD 7 x 3.5cm (2.75 x 1.375") | Graphical LCD 7 x 3.5cm (2.75 x 1.375") |
Resolution | 0.01ppm | 1ppm | 0.00% | 0.10% |
Enclosure |
Painted aluminum NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3") 3.64kg (8lbs) |
Painted aluminum NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3") 3.64kg (8lbs) |
Painted aluminum NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3") 3.64kg (8lbs) |
Painted aluminum NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3") 3.64kg (8lbs) |
Compensation | Barometric pressure and temperature | Barometric pressure and temperature | Barometric pressure and temperature | Barometric pressure and temperature |
Signal output | 0-1V | 0-1V | 0-1V | 0-1V |
LED indicators | LOW BATT (72 hr. warning); CHARGE mode | LOW BATT (72 hr. warning); CHARGE mode | LOW BATT (72 hr. warning); CHARGE mode | LOW BATT (72 hr. warning); CHARGE mode |
Operating temperature |
5°C to 45°C (41°F to 113°F) (GPR sensor), -10° to 45°C (14°F to 113°F) (XLT sensor) |
5°C to 45°C (41°F to 113°F) (GPR sensor), -10° to 45°C (14°F to 113°F) (XLT sensor) |
5°C to 45°C (41°F to 113°F) (GPR sensor), -10° to 45°C (14°F to 113°F) (XLT sensor) |
5°C to 45°C (41°F to 113°F) |
Power | Rechargeable battery (lead acid) | Rechargeable battery (lead acid) | Rechargeable battery (lead acid) | Rechargeable battery (lead acid) |
Battery life | Up to 30 days on a single charge (40 hours with pump running) | Up to 30 days on a single charge (40 hours with pump running) | Up to 30 days on a single charge (40 hours with pump running) | Up to 30 days on a single charge |
Area classification |
ATEX: Ex II 2 G Ex ib IIC T4 Gb Tamb: 5°C to +45°C |
ATEX: Ex II 2 G Ex ib IIC T4 Gb Tamb: 5°C to +45°C |
ATEX: Ex II 2 G Ex ib IIC T4 Gb Tamb: 5°C to +45°C |
General purpose only |
Customer Service QQ
Customer Hotline:
Technical Supports