Products

current position:home page>Products>Measuring Instrument>Pulsar>

IMP I.S. ATEX Level Sensor

Updated:2024-04-01

Views:714

  • Brand: Pulsar
  • Model: IMP I.S.
  • Product description: The IMP range of level sensors feature a combined transducer and controller in one self-contained unit. All IMP units from Pulsar Measurement are non-contacting, accurate, and reliable level measureme
  • Feedback
  • WeChat

    QQ

    Online Service

product details

IMP I.S. ATEX Level Sensor Description:

User's Manual Datasheet

The IMP range of level sensors feature a combined transducer and controller in one self-contained unit. All IMP units from Pulsar Measurement are non-contacting, accurate, and reliable level measurement units. The IMP level sensors do not come into contact with the process, therefore there is no need to shut down or interrupt operations. Featuring specially designed digital echo processing technology, the IMP level measurement units provide simple, accurate, and reliable level measurement on their onboard LCD displays.

The IMP I.S. level sensor is certified to ATEX standard EEx ia IIC T4 and IECEx, and is available with wetted parts in PVDF, making it ideal for measuring in corrosive or aggressive applications. Available in three measurement sizes from 3 m to 10 m (9.8 ft to 32.8 ft) the unit is simple and straightforward to set up using the onboard keypad and menu-led programming system.

Features

Compact and self-contained level measurement

Simple menu led setup

High power and narrow beam angles

High specification ATEX

Up to 10 m (32.8 ft) range available

Specifications

Dimensions 186 mm H x 133 mm D (7.3 in H x 5.2 in D)
Cable Entry 2 x cable glands 4.5 mm to 10 mm (0.2 in to 0.4 in) (Torque to 2 NM)
Mounting IMP3 - 3 m (9.8 ft) version: 1.5 in BSP/NPT
IMP 6 - 6 m (19.7 ft) version: 1.5 in BSP/NPT
IMP10 - 10 m (32.8 ft) version: 2 in BSP/NPT
Suits BSP & NPT, parallel and tapered
Weight Nominal 1 kg (2.2 lb)
Enclosure Protection IP67
Temperature (Ambient) -40 °C to +6 5 °C (-40 °F to +149 °F)
Temperature (Process) -40 °C to +80 °C (-40 °F to +176 °F)
Input Voltage Range 11-30 V, 3.5-22mA
Accuracy ±0.25% or 6 mm (0.2 in); whichever is greater
Resolution ±0.1% or 2 mm (0.1 in); whichever is greater
4-20mA Outputs Resolution 5 μA (both active and passive outputs)
Temperature Compensation Via internal temperature sensor (0.5 °C (± 32.9 °F) accuracy). Level and volume conversion are installed allowing linearisation for tank shapes.
PC Interface All parameters can be accessed and changed through PC Suite software. Echo traces may be viewed on-screen.

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com