Products

current position:home page>Products>Environmental Instrument>

LI-191R Line Quantum Sensor

Updated:2023-07-14

Views:1307

  • Brand: LI-COR
  • Model: LI-191R
  • Description: The LI-191R Line Quantum Sensor measures PAR integrated over its 1-meter length. It is used to measure sunlight under a plant canopy, where the light field is non-uniform. The LI-191R makes it easy to
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

LI-191R Line Quantum Sensor Description:

Product Manual

The LI-191R Line Quantum Sensor measures PAR integrated over its 1-meter length. It is used to measure sunlight under a plant canopy, where the light field is non-uniform. The LI-191R makes it easy to measure under-canopy light in many plots quickly and consistently. It measures light in units of Photosynthetic Photon Flux Density (PPFD), which is expressed as μmol s-1 m-2.

Character

Improved water resistance for long-term outdoor deployment

Integrated measurements using a single detector prevents variance found in sensors that use multiple detectors

Selected by the National Ecological Observatory Network (NEON®) for integrated PAR measurements

Working Principle

The LI-191R uses a 1-meter long quartz rod under a diffuser to direct light to a single filtered silicon photodiode. The entire LI-191R diffuser is sensitive to light over its 1-meter length. Since the diffuser is one continuous piece, the LI-191R essentially integrates an infinite number of points over its surface into a single value that represents light from the entire 1-meter length. Optical filters block radiation with wavelengths beyond 700 nm, which is critical for under-canopy measurements, where the ratio of infrared to visible light may be high. The unique design of the LI-191R provides an excellent quantum response that is close to the ideal quantum response.

LI-191R Line Quantum Sensor Specification:

Absolute Calibration ± 10% traceable to National Institute of Science and Technology (NIST). The LI-191 is calibrated via transfer calibration using a reference LI-190R Quantum Sensor. Transfer error is ± 5% (included in the ± 10%)
Sensitivity Typically 7 μA per 1,000 μmol s-1 m-2 7μA
Linearity Maximum deviation of 1% up to 10,000 μmol s-1 m-2
Response Time 10μs
Temperature Dependence ± 0.15% per °C maximum
Cosine Correction Acrylic diffuser
Azimuth < ± 2% error over 360° at 45° elevation
Operating Temperature Range −40 °C to 65 °C
Relative Humidity Range 0% to 95% RH, Non-Condensing
Sensitivity Variation over Length ± 7% maximum using a 2.54 cm (1”) wide beam from an incandescent light source.
Sensing Area 1 m × 12.7 mm (39.4” × 0.50”)
Detector High stability silicon photovoltaic detector (blue enhanced)
Sensor Housing Weatherproof anodized aluminum housing with acrylic diffuser and stainless steel hardware.
Size 121.3 L × 2.54 W × 2.54 cm D (47.7” × 1.0” × 1.0”)
Weight 1.4 kg (3.0 lbs.)
Cable Length 3.1 m (10.0 ft.)

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com