Updated:2023-07-24
Views:1206
Online Service
Measuring only 88 mm (3.46″) in length and 18 mm (0.71″) in diameter, the Micro-Diver is Van Essen’s smallest Diver. The Micro-Diver® is a submersible datalogger for long-term, uninterrupted, real-time water level monitoring using a pressure sensor when submerged at a fixed level under the water surface. The pressure sensor measures the equivalent hydrostatic pressure of the water above the sensor diaphragm to calculate the total water depth. The Diver autonomously measures pressure and temperature and records them in its internal memory. The Diver is ideal for ground and surface water level applications.
The Micro-Diver is specifically designed for monitoring wells or drive-points too small to accommodate larger dataloggers. In addition to its compact size, the Micro-Diver’s memory capacity can store up to 48,000 measurements (date/time, pressure and temperature) – almost one measurement every ten minutes for an entire year.
The Micro-Diver has the following sample methods: fixed length intervals, event dependent, averaging and pumping test.
The Micro-Diver is available in the following pressure ranges: 10 m, 20 m, 50 m and 100 m..
Compact size: Ø 18 mm – length 88 mm
48,000 records of time stamp, pressure and temperature
30-Point Pressure Factory Calibration
Pre-programmed and user defined pumping tests
Fits ¾ inch drive points and piezometers
Event based, averaging and pumping tests sample methods to conserve memory
Cost effective frequent, long-term measuring
Reliable and accurate data
No need to search through extraneous data
Fits any application
Engineering and construction: Pump tests
Aquifer characterization: Pump and slug tests
Shallow water monitoring: Drive-points
Long-term groundwater monitoring: Small diameters wells
General | |||||
Length | 88 mm | ||||
Diameter | 15 mm | ||||
Memory | 48,000 measurements | ||||
Weight | 45 grams | ||||
Housing | stainless steel 316L | ||||
Sample interval | 0.5 second to 99 hours | ||||
Battery life | 10 years (dependent on usage) | ||||
Sample methods | fixed, event dependent, averaging, and pumping test | ||||
Temperature | |||||
Value | Unit | ||||
Range | -20 .. +80 | °C | |||
Accuracy | ±0.1 | °C | |||
Resolution | 0.01 | °C | |||
Pressure | |||||
Part No | DI601 | DI602 | DI605 | DI610 | Unit |
Range | 10 | 20 | 50 | 100 | meter |
Accuracy | ±1.0 | ±2.0 | ±5.0 | ±10.0 | cmH2O |
Resolution | 0.2 | 0.4 | 1.0 | 2.0 | cmH2O |