Feature Summary
Easy to install and remove
Install via 16 mm (5/8 in) drill hole or in the side of a trench
Tough, long-lasting body
No recalibration needed
Low salt sensitivity
Affordable
Excellent range (sensitivity from 0 kPa all the way to air dry [-100,000 kPa])
Onboard temperature measurement
Plug-and-play capability
Use with the ZL6 data logger for remote access to data on the cloud
DDI Serial and SDI-12 compatible
Measurement Specifications | Water Potential |
Range: 0 to –100,000 kPa (1.70 to 6.00 pF) Resolution: 0.1 kPa Accuracy: ±(10% of reading + 2 kPa) from –100 to –5 kPa NOTE: TEROS 22 can read up to 0 kPa when on a wetting path. The air entry of the soil limits the performance of the sensor to –5 kPa on the drying curve. NOTE: TEROS 22 is not well calibrated beyond –100 kPa. For more information on using the TEROS 21 beyond this range, see Section 3.3.3 in the user manual |
Dielectric Measurement Frequency | 70 MHz | |
Temperature |
Range: –40.00 to +60.00 °C Resolution: 0.10 °C Accuracy: ±1.00 °C |
|
Communication Specifications | Output | DDI serial or SDI-12 communication protocol |
Data Logger Compatibility | METER ZL6 and EM60 data loggers or any data acquisition system capable of 4.0- to 15-VDC power and serial or SDI-12 communication | |
Physical Specifications | Dimensions |
Diameter: 1.7 cm (0.67 in) Length: 17 cm (6.7 in) Length with optional extensions: 40, 40, and 120 cm (15.7, 31.5, and 47.3 in) |
Sensor Diameter | 1.7 cm (0.67 in) | |
Operating Temperature Range |
Minimum: –40.00 °C typical: NA Maximum: +60.00 °C NOTE: Sensors may be used at higher temperatures under certain conditions; contact Customer Support for assistance. |
|
Cable Length |
5 m (standard) 75 m (maximum custom cable length ) NOTE: Contact Customer Support if a nonstandard cable length is needed. |
|
Connector Types | Stereo plug connector or stripped and tinned wires | |
Connector Size | 3.50 mm | |
Conductor Gauge | 22-AWG \ 24-AWG ground wire | |
Electrical and Timing Characteristics | Supply Voltage (VCC to GND) |
Minimum: 4.0 VDC Typical: NA Maximum: 15.0 VDC |
Digital Input Voltage (Logic High) |
Minimum: 2.8 V Typical: 3.6 V Maximum: 5.0 V |
|
Digital Input Voltage (Logic Low) |
Minimum: –0.3 V Typical: 0.0 V Maximum: 0.8 V |
|
Digital Output Voltage (Logic High) |
Minimum: NA Typical: 3.6 V Maximum: NA |
|
Required Supply Current |
Minimum: 15 mA Typical: NA Maximum: NA |
|
Power Line Slew Rate |
Minimum: 1.0 V/ms Typical: NA Maximum: NA |
|
Power Up Time (DDI Serial) |
Minimum: NA Typical: 100 ms Maximum: 350 ms |
|
Time before sensor is responsive to SDI-12 commands (DDI serial enabled) |
Minimum: NA Typical: 260 ms Maximum: 500 ms |
|
Time before sensor is responsive to SDI-12 commands (DDI serial disabled) |
Minimum: NA Typical: 170 ms Maximum: NA |
|
Measurement Duration |
Minimum: NA Typical: 50 ms Maximum: NA |
|
Other | Compliance |
EM ISO/IEC 17050:2010 (CE Mark) EN 55011:2016 / A1:2017 (RCM Mark) |