Products

current position:home page>Products>Analysis Instrument>WIKA>

CPH7000 Portable process calibrator

Updated:2023-03-29

Views:1275

  • Brand: WIKA
  • Model: CPH7000
  • Description: The model CPH7000 process calibrator is a precise, portable calibrator for the calibration and checking of analogue pressure measuring instruments, pressure transmitters and process transmitters. The
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

CPH7000 Portable process calibrator Description:

Operating Instruction #1 Operating Instruction #2

General information

The model CPH7000 process calibrator is a precise, portable calibrator for the calibration and checking of analogue pressure measuring instruments, pressure transmitters and process transmitters. The CPH7000 in Ex version can also be used in hazardous areas. Furthermore, pressure switches can be checked and the switching point determined. With the CPH7000, not only can transmitters be checked, but also simulated and tested.

Design

The CPH7000 optionally features an integrated reference pressure sensor and also a manual pressure generation, with which pressures of -0.85 ... +25 bar [12.3 ... +360 psi] can be generated. It is possible to simultaneously power an external transmitter via the electrical module and to measure (or also simulate) its output signal.

Functions

The calibrator offers the possibility to set calibration routines quickly and easily, but also to run preconfigured calibration routines and automatically save the measured values. Over the WIKA-Wireless interface, the completed calibration processes can be transmitted to a PC. This data can subsequently be evaluated and archived using WIKA-CAL software. Thus a completely paperless transmitter calibration is possible with just the CPH7000.

Accuracy

The CPH7000 is temperature compensated and achieves an accuracy of 0.025 % of span. In order to avoid intricate calculations, the measured values can also be displayed directly in customer-specific units.

Applications

Calibration service companies and service industry

Measurement and control laboratories

Quality assurance

On-site calibration (safety also in hazardous areas)

Special features

Manual pressure generation of -0.85 … +25 bar [12.3 ... +360 psi]

Accuracy: 0.025 % FS (incl. calibration certificate)

Generation/measurement of 0 ... 24 mA and voltage supply DC 24 V

Data logger with high measuring rate and large memory

Intrinsically safe version