Oxygen Analyzers for Petrochemical - AII GPR-18/28

Updated:2023-10-20

Views:1122

  • Brand: PST/AII
  • Model: GPR-18/28
  • Description: Explosion-proof oxygen analyzers are designed for petrochemical industries processes containing hydrogen and other flammable gases. These trace and percentage oxygen analyzers are supplied in rugged E
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Oxygen Analyzers for Petrochemical - AII GPR-18/28 Description:

User’s Manual Datasheet

Explosion Proof O2 Solutions for Peterochemical Applications

Features

Galvanic electrochemical oxygen sensor technology

4 standard measurement ranges

Accuracy ±2% of selected range

Sensitivity < 0.5% of range

Long O2 sensor life 24 to 36 months for low maintenance

No need for frequent electrolyte top-up

Field-proven superior electrochemical sensor stability

Flame arrestors fitted (standard)

Explosion-proof oxygen analyzers are designed for petrochemical industries processes containing hydrogen and other flammable gases. These trace and percentage oxygen analyzers are supplied in rugged Exd enclosures with flame arrestors and suitable for hazardous areas. The oxygen sensitivity of the field-proven electrochemical sensor allows oxygen measurement ranges from as low as 0-1 ppm up to 0-25% O2.

Specifications

GPR-18 MS-2 GPR-18 GPR-28
Measurement range 0-1 ppm, 0-10, 0-100 ppm & 0-1000 ppm 0-10 ppm, 0-100, 0-1000 ppm & 0-1%
(0-25% for calibration only)
0-1%, 0-5%, 0-10% & 0-25%
Accuracy < 2% of range < 2% of range < 2% of range
Response Time T90 < 20 seconds T90 < 10 seconds T90 < 10 seconds
Recovery Time O2 Level: Air
Duration: 30 Sec
O2 Target: 10 ppm
Recovery on N2: 45 minutes*

O2 Level: 9 ppm
Duration: 2 minutes
O2 Target: 0.1 ppm
O2 Level: Air
Duration: 2 minutes
O2 Target: 10 ppm
Recovery on N2: 60 minutes*

O2 Level: Air
Duration: 2 minutes
O2 Target: 1 ppm
Recovery on N2: 20 minutes**
O2 Level: Air
Duration: 30 sec
O2 Target: 0.1%
Recovery on N2: 30 seconds
* Installation * Installation
** In service for 2 weeks at 0.1 ppm
Sensitivity (LDL) < 0.5% of range < 0.5% of range < 0.5% of range
Linearity < 1% of scale < 1% of scale < 1% of scale
Sensor model GPR-12-2000MS GPR-12-333
XLT-12-333 (> 0.5% CO2 present)
GPR-11-32
XLT-11-24 (> 0.5% CO2 present)
Sensor life at 25ºC (77°F) and 1 atm 36 months; average O2 < 100 ppm 24 months; average O2 < 100 ppm GPR-11-32 32 months in air;
XLT-11-24 24 months in air
Calibration interval 1-3 months 1-3 months 1-3 months
Inlet pressure 0.34-2 barg (5-30 psig), max 100 psig; with atmospheric vent 0.34-2 barg (5-30 psig), max 100 psig; with atmospheric vent 0.34-2 barg (5-30 psig), max 100 psig; with atmospheric vent
Flow rate 0.5-1.0 l/m (1-2 SCFH) 0.5-1.0 l/m (1-2 SCFH) 0.5-1.0 l/m (1-2 SCFH)
Gas connections 1/8" or 1/4" compression tube fittings 1/8" or 1/4" compression tube fittings 1/8" or 1/4" compression tube fittings
Wetted parts Stainless steel Stainless steel Stainless steel
Display 3½ digit bright red LED; resolution 0.01 ppm GPR-18, 0.001 PPM GPR-18MS2, 0.001% GPR-28 3½ digit bright red LED; resolution 0.01 ppm GPR-18, 0.001 PPM GPR-18MS2, 0.001% GPR-29 3½ digit bright red LED; resolution 0.01 ppm GPR-18, 0.001 PPM GPR-18MS2, 0.001% GPR-30
Enclosure - UL Aluminum 30.4 x 29.2 x 26.7cm (12 x 11.5 x 10.5”) wall mount, 22.7kg (50lbs) Aluminum 30.4 x 29.2 x 26.7cm (12 x 11.5 x 10.5”) wall mount, 22.7kg (50lbs) Aluminum 30.4 x 29.2 x 26.7cm (12 x 11.5 x 10.5”) wall mount, 22.7kg (50lbs)
Enclosure - ATEX Aluminum 40.6 x 45.7 x 27.9cm (16 x 18 x 11”) wall mount, 31.8kg (70lbs) Aluminum 40.6 x 45.7 x 27.9cm (16 x 18 x 11”) wall mount, 31.8kg (70lbs) Aluminum 40.6 x 45.7 x 27.9cm (16 x 18 x 11”) wall mount, 31.8kg (70lbs)
Compensation Temperature Temperature Temperature
Signal output 4-20 mA isolated and 0-1V 4-20 mA isolated and 0-1V 4-20 mA isolated and 0-1V
Alarms 2 adjustable form C relay contacts non-latching; sensor and power failure 3 adjustable form C relay contacts non-latching; sensor and power failure 4 adjustable form C relay contacts non-latching; sensor and power failure
Operating temperature 5°C to 45°C (41°F to 113°F) GPR Sensor: 5°C to 45°C (41°F to 113°F)
XLT Sensor: -10° to 45°C (14°F to 113°F)
GPR Sensor: 5°C to 45°C (41°F to 113°F)
XLT Sensor: -10° to 45°C (14°F to 113°F)
Power 100/120 or 220/240 V AC 100/120 or 220/240 V AC 100/120 or 220/240 V AC
Certifications Conforms to UL: Class 1, Division 1, Groups B, C, D NEMA4/7 hazardous areas (enclosures only) ATEX: EExd d IIB+H2 T6 Conforms to UL: Class 1, Division 1, Groups B, C, D NEMA4/7 hazardous areas (enclosures only) ATEX: EExd d IIB+H2 T6 Conforms to UL: Class 1, Division 1, Groups B, C, D NEMA4/7 hazardous areas (enclosures only) ATEX: EExd d IIB+H2 T6