Explosion Proof O2 Solutions for Peterochemical Applications
Features
Galvanic electrochemical oxygen sensor technology
4 standard measurement ranges
Accuracy ±2% of selected range
Sensitivity < 0.5% of range
Long O2 sensor life 24 to 36 months for low maintenance
No need for frequent electrolyte top-up
Field-proven superior electrochemical sensor stability
Flame arrestors fitted (standard)
Explosion-proof oxygen analyzers are designed for petrochemical industries processes containing hydrogen and other flammable gases. These trace and percentage oxygen analyzers are supplied in rugged Exd enclosures with flame arrestors and suitable for hazardous areas. The oxygen sensitivity of the field-proven electrochemical sensor allows oxygen measurement ranges from as low as 0-1 ppm up to 0-25% O2.
Specifications
GPR-18 MS-2 | GPR-18 | GPR-28 | |
Measurement range | 0-1 ppm, 0-10, 0-100 ppm & 0-1000 ppm |
0-10 ppm, 0-100, 0-1000 ppm & 0-1% (0-25% for calibration only) |
0-1%, 0-5%, 0-10% & 0-25% |
Accuracy | < 2% of range | < 2% of range | < 2% of range |
Response Time | T90 < 20 seconds | T90 < 10 seconds | T90 < 10 seconds |
Recovery Time |
O2 Level: Air Duration: 30 Sec O2 Target: 10 ppm Recovery on N2: 45 minutes* O2 Level: 9 ppm Duration: 2 minutes O2 Target: 0.1 ppm |
O2 Level: Air Duration: 2 minutes O2 Target: 10 ppm Recovery on N2: 60 minutes* O2 Level: Air Duration: 2 minutes O2 Target: 1 ppm Recovery on N2: 20 minutes** |
O2 Level: Air Duration: 30 sec O2 Target: 0.1% Recovery on N2: 30 seconds |
* Installation |
* Installation ** In service for 2 weeks at 0.1 ppm |
||
Sensitivity (LDL) | < 0.5% of range | < 0.5% of range | < 0.5% of range |
Linearity | < 1% of scale | < 1% of scale | < 1% of scale |
Sensor model | GPR-12-2000MS |
GPR-12-333 XLT-12-333 (> 0.5% CO2 present) |
GPR-11-32 XLT-11-24 (> 0.5% CO2 present) |
Sensor life at 25ºC (77°F) and 1 atm | 36 months; average O2 < 100 ppm | 24 months; average O2 < 100 ppm |
GPR-11-32 32 months in air; XLT-11-24 24 months in air |
Calibration interval | 1-3 months | 1-3 months | 1-3 months |
Inlet pressure | 0.34-2 barg (5-30 psig), max 100 psig; with atmospheric vent | 0.34-2 barg (5-30 psig), max 100 psig; with atmospheric vent | 0.34-2 barg (5-30 psig), max 100 psig; with atmospheric vent |
Flow rate | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) |
Gas connections | 1/8" or 1/4" compression tube fittings | 1/8" or 1/4" compression tube fittings | 1/8" or 1/4" compression tube fittings |
Wetted parts | Stainless steel | Stainless steel | Stainless steel |
Display | 3½ digit bright red LED; resolution 0.01 ppm GPR-18, 0.001 PPM GPR-18MS2, 0.001% GPR-28 | 3½ digit bright red LED; resolution 0.01 ppm GPR-18, 0.001 PPM GPR-18MS2, 0.001% GPR-29 | 3½ digit bright red LED; resolution 0.01 ppm GPR-18, 0.001 PPM GPR-18MS2, 0.001% GPR-30 |
Enclosure - UL | Aluminum 30.4 x 29.2 x 26.7cm (12 x 11.5 x 10.5”) wall mount, 22.7kg (50lbs) | Aluminum 30.4 x 29.2 x 26.7cm (12 x 11.5 x 10.5”) wall mount, 22.7kg (50lbs) | Aluminum 30.4 x 29.2 x 26.7cm (12 x 11.5 x 10.5”) wall mount, 22.7kg (50lbs) |
Enclosure - ATEX | Aluminum 40.6 x 45.7 x 27.9cm (16 x 18 x 11”) wall mount, 31.8kg (70lbs) | Aluminum 40.6 x 45.7 x 27.9cm (16 x 18 x 11”) wall mount, 31.8kg (70lbs) | Aluminum 40.6 x 45.7 x 27.9cm (16 x 18 x 11”) wall mount, 31.8kg (70lbs) |
Compensation | Temperature | Temperature | Temperature |
Signal output | 4-20 mA isolated and 0-1V | 4-20 mA isolated and 0-1V | 4-20 mA isolated and 0-1V |
Alarms | 2 adjustable form C relay contacts non-latching; sensor and power failure | 3 adjustable form C relay contacts non-latching; sensor and power failure | 4 adjustable form C relay contacts non-latching; sensor and power failure |
Operating temperature | 5°C to 45°C (41°F to 113°F) |
GPR Sensor: 5°C to 45°C (41°F to 113°F) XLT Sensor: -10° to 45°C (14°F to 113°F) |
GPR Sensor: 5°C to 45°C (41°F to 113°F) XLT Sensor: -10° to 45°C (14°F to 113°F) |
Power | 100/120 or 220/240 V AC | 100/120 or 220/240 V AC | 100/120 or 220/240 V AC |
Certifications | Conforms to UL: Class 1, Division 1, Groups B, C, D NEMA4/7 hazardous areas (enclosures only) ATEX: EExd d IIB+H2 T6 | Conforms to UL: Class 1, Division 1, Groups B, C, D NEMA4/7 hazardous areas (enclosures only) ATEX: EExd d IIB+H2 T6 | Conforms to UL: Class 1, Division 1, Groups B, C, D NEMA4/7 hazardous areas (enclosures only) ATEX: EExd d IIB+H2 T6 |