Proper wiring is crucial to ensure safety and performance of Branch circuits. From a safety perspective, shock hazards and fires are mainly due to poor installation or failure of protective devices, such as GFCIs. From a performance perspective, electrical equipment and high-tech devices are found everywhere in residential and commercial buildings. They require reliable power to operate and function properly to ensure their longevity.
The unit is designed for 120 volts AC Hot Neutral and Ground only. It is protected in the event of a miswired outlet in the US electrical system to 240 VAC, but should be immediately unplugged and no tests performed until the voltage is corrected. Obviously that is not applicable in countries where the standard voltage is 240 H to N. The unit is not intended for nor is suitable for any other use than 120 VAC at 60 hertz.
Features
Designed for 120 Volts AC Hot Neutral and Ground
Measures Ground Impedance per ANSI/ESD S6.1
Neutral & Ground Wires Verification per ANSI/ESD S6.1
Verifies that Hot & Neutral are not reversed
Verifies that Hot & Equipment Ground are not reversed
Line Voltage
True RMS
Peak Voltage
Ground to neutral voltage
Frequency
Hot and neutral conductor impedances
Identifies false (bootleg) grounds
Tests GFCIs and EPDs for proper operation
Identifies proper wiring in 3-wire receptacles
Technical Specifications
Characteristics | Ranges | Resolution | Basic Accuracy2 |
Line Voltage | 85.0 - 265.0 VAC | 0.1V | 1.0% ± .2V |
Peak Line Voltage | 121.0 - 354.0 VAC | 0.1V | 1.0% ± .2V |
Frequency | 45.0 - 65.0 Hz | 0.1Hz | 1.0% ± .2Hz |
% Voltage Drop | 0.1% - 99.9% | 0.1% | 2.5% ± .2% |
Voltage Loaded | 10.0 - 132.0 VAC | 0.1V | 2.5% ± .2V |
Neutral-Ground V | 0.0 - 10.0 VAC | 0.1V | 2.5% ± .2V |
Impedance - Hot | 0.00 Ω - 3.00 Ω | 0.01 Ω | 2.5% ± .02 Ω |
Neutral, & Ground | > 3 Ω | Unspecified | |
GFCI Trip Time | 1mS to 6.500S counter | 1 mS | 1.0% ± 2mS |
GFCI Trip Current | 6.0 - 9.0 mA | 0.1 mA | 1.0% ± .2mA |
EPD Trip Current | 30.0 - 37.0 mA | 0.1 mA | 1.0% ± .2mA |
Estimated Load on Line | 1.00 – 20.0A | 0.1A | Unspecified |
Characteristics | |
Display | 128 x 64 OLED with backlight |
Display update for Volt | Less than 2.5 times Second |
Over-range Indication on all functions | Display “OL” |
Operating Environment | 32°F to 122°F (0°C to 50°C) at <80%RH |
Storage Environment | 32°F to 122°F (0°C to 50°C) at <80% RH |
Altitude | 6561.7 ft (2000m) |
Case Construction | ABS UL 94V/0/5VA rated |
Dimensions (LxWxD) |
6.4” x 3.0” x 1.4” 162mm x 76mm x 36mm |
Weight | 9.4 oz (267g) |
Safety |
UL61010B-1, Cat III-300V UL-1436 for AFCI, GFCI & Outlet |
Warranty | 2-year warranty |