Updated:2023-10-23
Views:1344
Online Service
Monitors Oxygen in General Purpose and Hazardous Areas
Features
Advanced galvanic electrochemical sensors
Measuring oxygen in ranges: 0-1% up to 0-100% (model dependant)
Accuracy of better than 2% of selected range
Auto-ranging or fixed range (user selectable)
Long lifespan of the GPR sensor of 32 months and more
Simple to use HMI
The GPR-2500 is an industrial oxygen analyzer for percentage oxygen measurements in both general purpose or hazardous areas. Available in several variants, all of which are supplied in a lightweight NEMA enclosure with stainless steel wetted parts and easy to access electrochemical oxygen sensors for user-friendly maintenance.
Specifications
GPR-2500 N (ATEX) | GPR-2500 A | GPR-2500 MON | GPR-2500 AMO | |
Measurement range | 0-1%, 0-5%, 0-10%, 0-25% | 0-1%, 0-5%, 0-10%, 0-25% | 0-100% | 0-100% |
Accuracy | < 2% of range at constant conditions | < 2% of range at constant conditions | < 2% of range at constant conditions | < 2% of range at constant conditions |
Response time | T90 < 10 seconds | T90 < 10 seconds | T90 < 13 seconds | T90 < 13 seconds |
Sensitivity (LDL) | < 0.5% of scale | < 0.5% of scale | < 0.5% of scale | < 0.5% of scale |
Linearity | <1% of scale | <1% of scale | <1% of scale | <1% of scale |
Sensor model |
GPR-11-32-4 XLT-11-24-4 for gases containing > 0.5% CO2 |
GPR-11-32-4 XLT-11-24-4 for gases containing > 0.5% CO2 |
GPR-11-120-4 | GPR-11-120-4 |
Sensor life in air at 25°C (77°F) and 1 atm |
GPR-11-32-4: 32 months XLT-11-24-4: 24 months |
GPR-11-32-4: 32 months XLT-11-24-4: 24 months |
GPR-11-120-4: 24 months in 100% O2 | |
Calibration interval | 30 days | 30 days | 30 days | 30 days |
Inlet pressure | 0.34-2 barg (5-30 psig) with atmospheric vent | 0.34-2 barg (5-30 psig) with atmospheric vent | 0.34-2 barg (5-30 psig) with atmospheric vent | 0.34-2 barg (5-30 psig) with atmospheric vent |
Flow rate | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) | 0.5-1.0 l/m (1-2 SCFH) |
Gas connections | 1/8" compression tube fittings | 1/8" compression tube fittings | 1/8" compression tube fittings | 1/8" compression tube fittings |
Wetted parts | Stainless steel | Stainless steel | Stainless steel | Stainless steel |
Display | Graphical LCD 7 x 3.5cm (2.75 x 1.375”); resolution 0.001% | Graphical LCD 7 x 3.5cm (2.75 x 1.375”); resolution 0.001% | Graphical LCD 7 x 3.5cm (2.75 x 1.375”); resolution 0.1% | Graphical LCD 7 x 3.5cm (2.75 x 1.375”); resolution 0.1% |
Enclosure | Fiberglass NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3") | Fiberglass NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3") | Fiberglass NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3") | Fiberglass NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3") |
Weight | 3.6kg (8lbs) | 3.6kg (8lbs) | 3.6kg (8lbs) | 3.6kg (8lbs) |
Compensation | Temperature | Barometric pressure and temperature | Temperature | Barometric pressure and temperature |
Signal output | 4-20 mA | 4-20 mA | 4-20 mA | 4-20 mA |
Alarms | N/A | Two user configurable alarms: magnetic coil relays rated 3A at 100 V AC | N/A | Two user configurable alarms: magnetic coil relays rated 3A at 100 V AC |
Operating temperature |
GPR sensor: 5°C to 45°C (41°F to 113°F) XLT sensor: -10° to 45°C (14°F to 113°F) |
GPR sensor: 5°C to 45°C (41°F to 113°F) XLT sensor: -10° to 45°C (14°F to 113°F) |
GPR sensor: 5°C to 45°C (41°F to 113°F) XLT sensor: -10° to 45°C (14°F to 113°F) |
GPR sensor: 5°C to 45°C (41°F to 113°F) XLT sensor: -10° to 45°C (14°F to 113°F) |
Power | 18-24 V DC | 12-28V DC non-loop or 110-220 V AC | 18-24 V DC | 12-28 V DC non-loop or 110-220 V AC |
Area Classification |
II 2 G Ex ia IIB T4 Gb Tamb -20°C to +50°C |
Customer Service QQ
Customer Hotline:
Technical Supports