Products

current position:home page>Products>Measuring Instrument>Hukseflux>

SR15-D1 Digital First Class Pyranometer

Updated:2023-05-29

Views:1109

  • Brand: Hukseflux
  • Model:SR15-D1
  • Description: SR15 digital pyranometer series is a range of high-accuracy digital solar radiation sensors. It is “first class” according to the WMO guide and ISO 9060:1990 standard and “Spectrally Flat Class B” in
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

SR15-D1 Digital First Class Pyranometer: User's Manual Datasheet


PV System Performance Monitoring: Compliant with IEC Class B

IEC 61724-1: Photovoltaic System Performance Monitoring – Guidelines for Measurement, Data Exchange and Analysis – requires heating for Class B monitoring. SR15-D1, with its on-board heater, offers Class B compliance without the need for additional accessories.

SR15 Digital Series Design

SR15 first class pyranometer employs a thermal sensor with black coating, two glass domes and an anodized aluminium body. The digital sensor offers output via Modbus RTU over 2-wire RS-485 (version SR15-D1) and via Modbus TTL and 4-20 mA current loop (version SR15-D2A2).

Suggested Use

  • PV system performance monitoring
  • General solar resource monitoring
  • Indoor simulated solar testing
  • Meteorological networks
  • Areas of Application

  • Meteorology / surface energy flux measurement
  • Solar energy / PV system performance monitoring
  • SR15-D1 Digital First Class Pyranometer Specifications:

    Measurand Hemispherical solar radiation
    ISO 9060:2018 classification spectrally flat Class B (first class)
    IEC 61724-1:2017 compliance Class B
    Application National Meteorological NetworksPV monitoring commercial and utility scale, PV monitoring small sized, meteorology / climatology, other
    Calibration uncertainty < 1.8 % (k = 2)
    Calibration traceability to WRR
    Spectral range 285 to 3000 x 10⁻⁹ m
    Response time < 10 s
    Zero offset a 5 W/m² unventilated
    Rated operating temperature range -40 to +80 °C
    Temperature response < ± 2 % (-10 to +40 °C)
    Heater 1.5 W at 12 VDC
    Standard cable length 5 m
    Levelling optional spring-loaded levelling, with / without tube mount
    Communication protocol Modbus over 2-wire RS-485
    Transmission mode RTU
    Output irradiance in W/m² and instrument body temperature in °C
    On-board heater included
    Version order codes SR15-D1, SR15-D1-LM01, SR15-TLM01
    Options • Spring-loaded levelling; practical for easy mounting, levelling and instrument exchange on flat surfaces (LM01)
    • Tube levelling mount with set of bolts (TLM01)
    • PMF01 bracket for tilted installations
    • Longer cable; 10 and 20 metres length
    • 20 metres extension cable with 2 connectors

    WeChat

    Customer Service QQ

    Customer Hotline:

    010-52867770
    0l0-52867771
    l3811111452
    l7896OO5796

    Technical Supports

    0l0-52867774
    l7896OO5796
    info@dorgean.com