| Measurand | Hemispherical solar radiation | 
| ISO 9060:2018 classification | spectrally flat Class B (first class) | 
| IEC 61724-1:2017 compliance | Class B | 
| Application | National Meteorological NetworksPV monitoring commercial and utility scale, PV monitoring small sized, meteorology / climatology, other | 
| Calibration uncertainty | < 1.8 % (k = 2) | 
| Calibration traceability | to WRR | 
| Spectral range | 285 to 3000 x 10⁻⁹ m | 
| Response time | < 10 s | 
| Zero offset a | 5 W/m² unventilated | 
| Rated operating temperature range | -40 to +80 °C | 
| Temperature response | < ± 2 % (-10 to +40 °C) | 
| Heater | 1.5 W at 12 VDC | 
| Standard cable length | 5 m | 
| Levelling | optional spring-loaded levelling, with / without tube mount | 
| Communication protocol | Modbus over 2-wire RS-485 | 
| Transmission mode | RTU | 
| Output | irradiance in W/m² and instrument body temperature in °C | 
| On-board heater | included | 
| Version order codes | SR15-D1, SR15-D1-LM01, SR15-TLM01 | 
| Options | • Spring-loaded levelling; practical for easy mounting, levelling and instrument exchange on flat surfaces (LM01) • Tube levelling mount with set of bolts (TLM01) • PMF01 bracket for tilted installations • Longer cable; 10 and 20 metres length • 20 metres extension cable with 2 connectors | 